TEC, INCORPORATED -- TEC MAX BOND MULTIPURPOSE CONSTRUCTION ADHESIVE -- 8040-00N060212
=====================  Product Identification  =====================

Product ID:TEC MAX BOND MULTIPURPOSE CONSTRUCTION ADHESIVE
MSDS Date:09/29/1993
FSC:8040
NIIN:00N060212
=== Responsible Party ===
Company Name:TEC, INCORPORATED
Address:315 SOUTH HICKS RD
City:PALATINE
State:IL
ZIP:60067
Country:US
Info Phone Num:708-358-9500
Emergency Phone Num:800-228-5635
Preparer's Name:T CASSUTT
CAGE:JO050
=== Contractor Identification ===
Company Name:HB FULLER CO.
Address:315 SOUTH HICKS ROAD
Box:City:PALATINE
State:IL
ZIP:60067
Country:US
Phone:847-358-9500/612-236-5842
CAGE:5P957
Company Name:TEC, INCORPORATED
Address:315 SOUTH HICKS RD
Box:City:PALATINE
State:IL
ZIP:60067
Country:US
Phone:708-358-9500
CAGE:JO050

=============  Composition/Information on Ingredients  =============

Ingred Name:SILICA, CRYSTALLINE - QUARTZ; (CRYSTALLINE SILICA)
CAS:14808-60-7
RTECS #:VV7330000
Fraction by Wt: 1-10%
OSHA PEL:SEE TABLE Z-3
ACGIH TLV:0.1 MG/M3 RDUST

Ingred Name:HEXANE; (N-HEXANE) (CERCLA) LEL:1.2% VP:120 @ 20C
CAS:110-54-3
RTECS #:MN9275000
Fraction by Wt: >10%
OSHA PEL:500 PPM
ACGIH TLV:50 PPM
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:VOLATILE ORGANIC COMPOUND:278 @ VOC/LITER OF MATERIAL/LESS
    WATER AND EXEMPT SOLVENTS.
RTECS #:9999999VO
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:ACUTE:HARMFUL IF SWALLOWED. EYE
    CONTACT MAY CAUSE IRRITATION. PROLONGED OR REPEATED SKIN CONTACT
    MAY CAUSE IRRITATION AND DERMATITIS. INHALATION OF HIGH VAPOR
    CONCENTRATIONS MAY CAUSE IRRITATIONS OF T HE NOSE, THROAT, AND
    RESPIRATORY TRACT AND MAY CAUSE DIZZINESS, HEADACHES, NAUSEA OR
    UNCONSCIOUSNESS. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ:IRAC
    MONOGRAPHS, SUPP. VOL 7, PG 341, 1987:GROUP 2A. NTP 7TH ANNUAL RPT
    ON CARCINS. (SUP DAT)
Effects of Overexposure:HLTH HAZS:CHRONIC:LONG TERM OVEREXPOSURE TO
    SOLVENTS MAY CAUSE LIVER AND KIDNEY DAMAGE. N-HEXANE HAS BEEN
    DEMONSTRATED TO CAUSE PERIPHERAL NERVE DAMAGE IN OVEREXPOSED
    WORKERS. SYMPTOMS INCLUDE LOSS OF  FEELING AND WEAKNESS IN THE
    HANDS AND FEET AND LOSS OF MANUAL DEXTERITY.
Medical Cond Aggravated by Exposure:NO KNOWN EFFECTS OTHER THAN
    ILLNESS.

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH IMMEDIATELY WITH WATER FOR AT LEAST 15 MINUTES.
    GET IMMEDIATE MEDICAL ATTENTION. SKIN:WASH AFFECTED AREA WITH SOAP
    AND WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE.
    INHALATI ON:REMOVE FROM EXPOSURE. KEEP WARM AND QUIET. GET MEDICAL
    ATTENTION. INGESTION:DO NOT INDUCE VOMITING. GET MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:<0F,<-18C
Lower Limits:SEE ING 2
Extinguishing Media:USE WATER SPRAY, FOAM, DRY CHEMICAL OR CARBON
    DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY RUPTURE WHEN
    EXPOSED TO EXTREME HEAT. WATER SPRAY MAY BE USED TO COOL
    CONTAINERS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE
    AREA. AVOID BREATHING VAPORS. SCRAPE UP AND TRANSFER TO CONTAINER
    FOR DISPOSAL. USE NON-SPARKING TOOLS. KEEP SPILL OUT OF SEWAGE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COMPLIANCE WITH OSHA
    1910.106. DO NOT STORE NEAR HEAT, SPARKS OR FLAME.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED EQUIPMENT. ORGANIC VAPOR
    RESPIRATORS WHEN AIRBORNE EXPOSURE LIMITS ARE EXCEEDED.
Ventilation:PROVIDE VENTILATION TO CONTROL CONTAMINANT LEVELS BELOW
    AIRBORNE EXPOSURE LIMITS.
Protective Gloves:RUB GLOVES REC FOR PRLNG/RPTD CONT.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYE WASH & DELUGE SHOWER WHICH
    MEET ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:1994:ANTICIPATED TO BE CARCINOGEN.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>156F,>69C
Vapor Pres:SEE ING 2
Spec Gravity:1.08 
Solubility in Water:NON-MISCIBLE
Appearance and Odor:LIQUID

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NOT ESTABLISHED.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION CAN YIELD LOW
    MOLECULAR WEIGHT HYDROCARBONS, CARBON MONOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:PROD MEETS DEFINITION HAZARDOUS WASTE UNDER U.S.
    EPA HAZARDOUS WASTE REGS 40 CFR 261. IT IS IGNITABLE WASTE CLASS
    D001. DISPOSAL VIA INCIN IS RECOMMENDED. CONSULT FED, STATE/LOC
    AUTHS  FOR PROPE R DISP IN EVENT MORE RESTRICTIVE REQS APPLY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.